For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
Performance Data |
|
| Supply voltage |
+24 V DC (+18-30 V DC) |
IEPE Interfaces |
|
| Type |
IEPE interface |
| Amount |
4 |
| Measurement range |
±0.172 ... ±5.5 V AC |
| Resolution |
16 bits |
| Conversion rate/channel |
≥ 5 µs (adjustable, default setting 5 µs) |
| Data recording/channel |
maximum 64 Word |
| Short-circuit proof, current limited |
Yes |
| Cable break monitor |
Yes |
| Hardware filter |
typically 31 MHz (high pass 1st order), typically 20 kHz (low pass 3rd order) |
Software Band Pass Filter |
|
| Lower frequency limit |
adjustable (minimum 0.1 Hz) |
| Upper frequency limit |
adjustable (maximum 10 kHz) |
| Processed measured values/cycle |
configurable |
| Output parameters |
Average Value, Minimum Value, Timestamp, Minimum Value, Timestamp, Maximum Value |
Sensor Supply |
|
| Adjustable current |
0, 4, 8, 12 mA individually adjustable for each channel |
| Supply voltage |
+18-30 V DC |
| Sensor voltage |
typically 19.1 V DC |
Mechanical Features |
|
| Dimensions |
12.5 x 104 x 72 mm (W x H x D) |
| Protection type |
IP20 |
Article Number/Certification |
|
| Article number |
20-009-040 |
| Standardization/certification |
UL 508 (E247993) |