Analog Input

AI 040

Analog Input

  • 4 analog inputs with IEPE interface
  • Signal conversion in frequency range of 31 mHz to 20 kHz (16 bits)
  • Max. sampling rate 50 kSPS
  • 5 µs offset between channels
  • Condition Monitoring

 

For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

Performance Data

Supply voltage

+24 V DC (+18-30 V DC)

IEPE Interfaces

Type

IEPE interface

Amount

4

Measurement range

±0.172 ... ±5.5 V AC

Resolution

16 bits

Conversion rate/channel

≥ 5 µs (adjustable, default setting 5 µs)

Data recording/channel

maximum 64 Word

Short-circuit proof, current limited

Yes

Cable break monitor

Yes

Hardware filter

typically 31 MHz (high pass 1st order), typically 20 kHz (low pass 3rd order)

Software Band Pass Filter

Lower frequency limit

adjustable (minimum 0.1 Hz)

Upper frequency limit

adjustable (maximum 10 kHz)

Processed measured values/cycle

configurable

Output parameters

Average Value, Minimum Value, Timestamp, Minimum Value, Timestamp, Maximum Value

Sensor Supply

Adjustable current

0, 4, 8, 12 mA individually adjustable for each channel

Supply voltage

+18-30 V DC

Sensor voltage

typically 19.1 V DC

Mechanical Features

Dimensions

12.5 x 104 x 72 mm (W x H x D)

Protection type

IP20

Article Number/Certification

Article number

20-009-040

Standardization/­certification

UL 508 (E247993)

Contact

We look forward to your inquiry!