For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
Performance Data |
|
| Supply voltage |
+18-55 V DC |
| Bus supply voltage |
+24 V DC |
| Current consumption of voltage supply |
maximum 5 A |
Digital Inputs |
|
| Type |
Enable |
| Number |
2 |
| Input voltage |
+24 V DC (+18-30 V DC) |
| Input current |
3 mA at +24 V |
| Input delay |
typically 0.5 ms |
Digital Outputs |
|
| Number |
1 |
| Short-circuit proof, current limited |
Yes |
| Max. load current/channel |
0.5 A |
| Output voltage |
+24 V DC (+18-30 V DC) |
| Max. Output current |
0.6 A |
Power Supply |
|
| Number |
1 |
| Type |
+24 V DC |
Incremental Encoder Input |
|
| Number |
1 |
| Input signals |
Incremental encoder signals RS422 (A, /A, B, /B, R, /R) RS422 signal (120 Ω termination) Incremental encoder signal TTL (A, B, R) TTL level (1200 Ω Pull-UP) |
| Input frequency |
adjustable via software, maximum value of input frequency between 125 Hz and 125 kHz |
| Counter frequency |
maximum 500 kHz |
| Resolution |
16 bits |
| Signal analysis |
4-port |
| Power supply |
+5 V/0.2 A short-circuit proof |
Regen Resistor |
|
| Type |
external power resistor |
| Output |
GND switching |
| Max. Current |
6 A |
Mechanical Features |
|
| Dimensions |
12.5 x 104 x 72 mm (W x H x D) |
| Protection type |
IP20 |
Article Number/Certification |
|
| Article number |
20-029-011 |