For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
Performance Data |
|
| Supply voltage |
+18-55 V DC |
Digital Inputs |
|
| Type |
+5 V DC |
| Number |
1 |
| Input voltage |
typically +5 V DC |
| Input current |
1.5 mA at +5 V |
| Input delay |
typically 5 ms |
Digital Inputs |
|
| Type |
+24 V DC |
| Number |
2 |
| Input voltage |
typically +24 V DC |
| Input current |
3.7 mA at +24 V |
| Input delay |
typically 5 ms |
Incremental Encoder Input |
|
| Number |
1 |
| Input signals |
Incremental encoder signals RS422 (A, /A, B, /B, R, /R) RS422 signal (120 Ω termination) Incremental encoder signals TTL (A, B, R) TTL level (1200 Ω Pull-Up) |
| Input frequency |
adjustable via software, maximum input frequency 400 Hz and 125 kHz |
| Counter frequency |
input frequency adjustable via software, maximum counter frequency 1.6 kHz and 500 kHz |
| Resolution |
16 bits |
| Signal analysis |
4-port |
| Power supply |
+5 V/0.2 A short-circuit proof |
Motor Output |
|
| Number |
1 |
| Supply voltage |
+12-30 V DC |
| Current |
0-3.5 A |
| Current measurement |
0-3.5 A |
Mechanical Features |
|
| Dimensions |
12.5 x 104 x 72 mm (W x H x D) |
| Protection type |
IP20 |
Article Number/Certification |
|
| Article number |
20-029-022 |
| Standardization/certification |
designed according to UL |