AI 022

Analog Input

  • 2 analog strain gauge inputs (24 bits)
  • For evaluating measuring bridges (e.g. strain gauge load cells)

For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

AI 022 - Analog Input

Technical data

Analog inputs

Type
strain gauge
Amount
2
Resolution
24 bits
Measuring range
±1.875 mV ... ±120 mV
Measuring accuracy
±0.0031 % noise with filter word 2
±0.001 % / °C temperature drift
Sensor break detection
Yes
Supply voltage of the bridges
+5 V DC
Load cell characteristic value
0.25-16 mV/V
Maximum vapors/channel
75-5000 Ω (when using one channel) / 150-5000 Ω (when using both channels)

Mechanical properties

Width (mm)
12.5
Height (mm)
104
Depth (mm)
72
Protection type
IP20

Article number / Certification

Item number
20-009-022
Standardization / Certification
UL 508 (E247993)
We MaxUp Your Automation
© 2026 SIGMATEK GmbH & Co KG